GB – Instructions for Series 9000 Masks
Important Information for Users
This manual is only valid in conjunction with the instruction manual for Moldex Series
7000/9000 gas and particulate filters. Failure to comply with these instructions on
how to use the product and failure to wear the respiratory protection in the polluted
area may negatively impact on the health of the user and lead to permanent damage
and life-threatening injuries.
• This breathing apparatus does not supply oxygen (02) • Only use the product in ad
-
equately ventilated areas,(19.5 Vol.-% oxygen) • The mask and filters must be selected
in accordance with the pollutant type and concentration (see Table 2). • In the case
of gases with insufficient warning properties, filters may only be used if special usage
policies are specified for this purpose. • If the conditions are uncertain or changeable,
self-contained breathing apparatus must be worn. • You must exit the working area
and replace the respirator mask immediately if: – the mask is damaged, – you expe
-
rience difficulty in breathing, – you experience dizziness or fatigue. – you can taste
or smell hazardous substances or if you experience irritation • Read the instruction
manual before using the mask. • The product does not contain any metallic parts that
could cause ignition in potentially explosive atmospheres. • If you have any questions
about how to use the product, please contact Moldex-Metric. • You must also observe
the relevant rules and regulations when using respiratory equipment. • Under certain
circumstances, persons with beards, long sideburns or other anomalies in the area
around the sealing lines may be unable to achieve a proper sealing fit. Spectacle
frames that extend under the sealing line will impede a proper sealing fit. • The masks
must not be modified in any way. • Users of the masks and filters must be familiar with
how to handle them correctly. • When not in use, the mask and filter must be stored in
an uncontaminated environment.
Caution: Do not use filter equipment in unventilated containers and confined spaces.
Preparations Before Using the Full-mask
The full-mask must always be checked before use. Do not use a damaged or defective
mask. Seek the immediate assistance of a supervisor.
You must check • The mask and the filters for fractures, deformations, cracks and
contamination. • Whether the head strap is torn, nicked or damaged in any other way
and whether it provides sufficient elasticity. • The inhalation and exhalation valves
as well as the sealing rings on the filter connections for contamination, deformation,
fractures and cracks. Make sure that the valves and sealing rings are fitted correctly. •
The use-by-date of the filter and their correct fitting in accordance with the instruction
manual for gas and particulate filters. Fitting/removing the full-mask (Figures 1, 2, 3
and 4) Open the straps fully at the 4 adjustment points and hold the head strap with
one hand at the bracing with the Moldex lettering. Place the opening of the head strap
at the back of the neck and pull the mask down over your face from above. At this point,
make sure that no hairs are trapped between the sealing lip and your face. Position
the mask on your face and use one hand to press the mask firmly against your mouth
and chin. Now use your other hand to pull the neck strap tight on one side and then
repeat the procedure on the other side. To ensure the best possible seal between mask
and face, you should always tighten the neck straps first. The head strap must lie flat
on your head. To ensure that the mask fits comfortably, adjust the head and neck strap
equally. Before entering your working area, check that the mask creates a seal around
the face. To remove the mask, first loosen the clips on the neck strap by pulling the mask
away from your face. Using suction to check the face seal (Figure 5) Place the palm
of your hand over the opening on the filter cover to seal it and breathe in slowly. If the
facepiece contracts slightly, the mask is correctly seated. If you notice an inflow of air,
adjust the position of the mask on your face or adjust the tension of the straps. Repeat
this check until a seal is achieved. Using excess pressure to check the face seal (Figure
6) For full-masks equipped with an EN 148-1 connection, check the face seal before
fitting the filter to the facepiece. Place the palm of your hand over the exhalation valve
and breathe out slowly. If no air escapes between the facepiece and your face, a prop
-
er sealing fit is achieved. If you notice air escaping, adjust the position of the mask on
your face or adjust the tension of the straps. Repeat this check until a seal is achieved.
Under no circumstances should you enter a hazardous area if you are unable to
achieve a proper sealing fit. Seek the assistance of a supervisor.
Maintaining the Full-mask
The maintenance intervals as set out in the national regulations must be adhered to.
The date of manufacture is shown on the inside of the face seal in the chin area.
Cleaning/Disinfection We recommend cleaning the mask after each use. If not in use,
clean the mask after 6 months at the latest. Remove the filter; clean the facepiece
with warm water (max. 50°C). If necessary, use a neutral cleaning agent and an
alcohol-based disinfectant. To clean the valve membrane, remove it from the holder.
To clean the inner mask, unfasten it from the two stop points. To refit it, use the guide
rails on the lower part of the lens and the two stop points. To dismantle the filter, refer
to the instruction manual for gas and particulate filters. After having cleaned or disin
-
fected the mask, the face seal needs to be checked by means of suitable leak testing
equipment. Before cleaning pull the protective film away from the lens Dry the mask
thoroughly before putting on a new protective film and before storing it. Storage Keep
the 9000 mask sealed in a dry, uncontaminated environment. Protect against sunlight
and sources of heat (see the "Storage" icons). The name of the wearer and a record
of the filter changes can be noted on the packaging. Caution: At low temperatures,
moisture can cause the valves to freeze up. The date of manufacture is engraved on
the inside of the mask. Calendar clocks see page 39. Exhalation Valve (Spare Part
No. 9974 [b]) Fold down the cover of the exhalation valve and check the exhalation
valve and valve seat for contamination, deformation, fractures or cracks. Replace the
valve membrane when necessary, or every 4 years at the latest. Please note date of
replacement. Inhalation Valve (Spare Part No. 9974 [a]) Check the inhalation valve
on the inner mask and on the inside of the filter connection for contamination, defor
-

Yapay zeka ile Moldex Series 9000 EasyLock kılavuzunuzla sohbet edin

Moldex Series 9000 EasyLock kılavuzunuzdan yapay zeka ile anında yanıt alın

Moldex Series 9000 EasyLock hakkında istediğinizi sorun. Yanıtlar bu kılavuzdan gelir ve dayandığı sayfalar belirtilir.

Series 9000 EasyLock Bakim Takvimi

Bakim zamani geldiginde bana hatirlat
Her 6 ayda bir
Kullanilmayan maskeyi temizleyin

Kullanilmiyorsa, hijyen ve islevselligi garanti altina almak icin maskeyi en az her 6 ayda bir temizleyin.

Kilavuzda goster (5. sayfa)
Her 4 yilda bir
Nefes verme valfi membranini degistirin

Gerektiginde veya en geic her 4 yilda bir nefes verme valfi membranini degistirin. Degistirme tarihini kaydedin.

Kilavuzda goster (5. sayfa)
Her kullanimdan sonra
Maskeyi temizleyin ve dezenfekte edin

Filtreleri cikarin ve yuz parcasini ilik suyla (maksimum 50°C) temizleyin. Gerekirse nor temizleyici/alkol bazli dezenfektan kullanin. Temizlikten sonra contayi kontrol edin.

Kilavuzda goster (5. sayfa)
Her kullanimdan once
Maskeyi ve valfleri inceleyin

Takmadan once maskeyi, filtreleri, bas bantlarini, nefes alma/verme valflerini ve conta halkalarini hasar, kirlilik veya sekil bozuklugu acisindan kontrol edin.

Kilavuzda goster (5. sayfa)

Ucretsiz bakim hatirlatmalari

Satın alma tarihinize göre zamanlanır. Her zaman ücretsizdir, istediğiniz zaman abonelikten çıkabilirsiniz.

Göndererek gizlilik politikasını kabul etmiş olursunuz. Herhangi bir e-postada tek tıklamayla abonelikten çıkabilirsiniz.
M: qwen/qwen3.8-flash

Soru Sor Soru

0/1000

Series 9000 EasyLock'i önerir misiniz?

Evet Hayır

Sıkça Sorulan Sorular

A

Hayır, bu solunum cihazı oksijen tedarik etmez. Sadece havalandırması yeterli olan ve en az %19.5 hacim oranında oksijen içeren alanlarda kullanım içindir.

Bu yanıt yardımcı oldu mu?

A

Her kullanım sonrası maskeyi temizlemeniz önerilir. Kullanılmıyorsa, kontaminasyon birikimini önlemek için en az altı ayda bir temizlenmelidir.

Bu yanıt yardımcı oldu mu?

A

Conta hattının altına uzanan gözlük çerçeveleri düzgün bir conta oturmasını engelleyecektir. İsteğe bağlı gözlük montajını kullanabilirsiniz ancak çerçevenin contayı bozmamasını sağlayın.

Bu yanıt yardımcı oldu mu?

A

Çalışma alanından hemen çıkmalı ve solunum cihazı maskesini değiştirmelisiniz. Tehlikeli maddelerin koklanması veya tadılması, conta veya filtre doygunluğunda bir ihlal olduğunu gösterir.

Bu yanıt yardımcı oldu mu?

A

Evet, ürün potansiyel olarak patlayıcı atmosferlerde kıvılcım çıkarma riski yaratabilecek herhangi bir metalik parça içermez ve bu tür ortamlar için güvenlidir.

Bu yanıt yardımcı oldu mu?

A

Filtre açıklığının üzerine elinizi koyarak yavaşça nefes vererek bir conta kontrolü yapın. Masla hafifçe büzülürse conta doğrudur. Alternatif olarak, nefes alma vanasını kapatıp hafifçe nefes vererek sızıntıları kontrol edin.

Bu yanıt yardımcı oldu mu?

M: QW-35-FL

Avantajlar ve Dezavantajlar

Avantajlar

  • Yüksek seviyede solunum koruması için EN 136:1998 CL2 standardına uygundur
  • EasyLock baş kayışı sistemi hızlı ve hassas ayarlama sağlar
  • Geniş bir P1, P2, P3 partikül ve gaz sınıfı filtre yelpazesine uyumludur
  • Potansiyel olarak patlayıcı atmosferlerde tutuşma risklerini azaltmak için metalik parça içermez
  • İsteğe bağlı gözlük montaj entegrasyonu ile net görüş polikarbonat lens
VS

Dezavantajlar

  • Uzun ömür sağlamak için bakım programlarına sıkı sıkıya uyulmasını gerektirir
  • Sakallar veya yüz tüyleri düzgün bir conta oturması elde edilmesini engelleyebilir
  • Conta hattının altına uzanan gözlük kolları contayı zayıflatabilir
  • Valfler nem varken düşük sıcaklıklara maruz kaldığında donabilir
  • Filtre seçimi spesifik kirletici türlerine ve konsantrasyonlara doğru bir şekilde eşleşmelidir
M: QW-35-FL

Ürün Özellikler

Özellikler

Vana, yüz kalkanı, dört nokta bağlama sistemi, ayarlanabilir, değiştirilebilir filtre

M: QW-35-FL

Ürün Açıklama

Moldex Serisi 9000 EasyLock Solunum Cihazıyla Akciğerlerinizi Koruyun

Moldex Serisi 9000 EasyLock Solunum Cihazı Tam Yüz Maskesi, zorlu endüstriyel ortamlar için tasarlanmış kişisel koruyucu ekipmanın bir zirvesi olarak durmaktadır. Bu sağlam tam yüz maskesi, toksik gazlar, buharlar ve partikül maddeler dahil olmak üzere çeşitli tehlikeli maddelere karşı kapsamlı koruma sunar. Sıkı EN 136:1998 CL2 standardını karşılamak üzere mühendislik hizmetiyle üretilmiştir ve kullanıcıların yaşamı tehdit eden kirleticilerden korunmasını sağlarken uzun süreli kullanımda konforu korur.

Bu solunum cihazının dikkat çeken özelliklerinden biri, maskeyi takmayı ve çıkarmayı basitleştiren yenilikçi EasyLock sistemidir. Baş kayışlarında dört ayarlama noktası bulunur ve çeşitli yüz şekillerine uyacak şekilde özelleştirilmiş bir uyum sağlar. Doğru sızdırmazlık çok önemlidir; maske ağzın ve çenenin etrafında hava geçirmez bir conta oluşturmalı ve saçları sıkıştırmamalı veya gözlük çerçevelerini engellememelidir. Kullanıcıların conta bütünlüğünü doğrulamak için herhangi bir kontamine alana girmeden önce hem negatif hem de pozitif basınç kontrolleri yapmaları tavsiye edilir.

Solunum koruması kullanırken bakım ve hijyen esastır. Kılavuz, yüz parçasının her kullanım sonrası en fazla 50 derece sıcaklıkta ılık suyla temizlenmesini önerir. Daha derin dezenfeksiyon için nötr temizleyiciler ve alkol bazlı dezenfektanlar kullanılabilir. Filtreyi çıkarmak, iç mask bileşenlerini temizlemek ve depolamadan önce valfleri enkaz veya hasar açısından kontrol etmek hayati önem taşır. Masla malzeme bozulmasını önlemek için her zaman doğrudan güneş ışığından ve ısı kaynaklarından uzakta kuru ve kontamine olmayan bir ortamda saklanmalıdır.

Çeşitlilik, Serisi 9000'in diğer önemli yönüdür. İşyeri Maruziyet Limitinin (WEL) 4 katını sunan P1 partikül filtrelerinden WEL'in 20 katına veya 5000 ppm'ye kadar çıkan Sınıf 2 gaz filtrelerine kadar çeşitli filtreleri destekler. 9004, 9005 ve 9006 gibi belirli modeller standartlaştırılmış filtre bağlantısı için EN 148-1 bağlantısını kullanır. Kimyasal işleme, tarım veya acil durum müdahalesinde çalışıyor olun, bu solunum cihazı sağlığınızı korumak için gereken güvenilirliği sağlar.

Önemli Bakım Notları

Nefes alma valfi membranını en az dört yılda bir değiştirin. Burun kupası ve baş kayışlarının aşınma açısından düzenli olarak incelenmesini sağlayın. Masla çatlak, deformasyon veya kontaminasyon belirtileri gösterirse hemen atın. Masla yapısını asla değiştirmeyin çünkü bu garantileri iptal eder ve güvenliği tehlikeye atar.

M: QW-35-FL

© Copyright 2026 Manual.ly